The RaVoR™ bipolar electrodes, single-use are designed for tissue-preserving volume reduction in ENT surgery. RaVoR stands for Radiofrequency Volume Reduction – a technique that uses targeted thermal energy to achieve controlled coagulation without placing unnecessary stress on surrounding structures.
The electrodes are available in various lengths and tip shapes and are suitable for applications on the turbinates, soft palate, tongue base, and other structures in the head and neck region. As sterile single-use products, they offer a ready-to-use solution without the need for cleaning – ideal for efficient use in the OR or outpatient setting.
RaVoR™ of the inferior turbinates has become a standard treatment option in sleep surgery, i.e. to treat habitual snoring, mild sleep apnea and to increase both comfort and compliance of CPAP treatment. Moreover, it can be beneficial to improve nasal breathing, even together with septum correction, or to treat symptoms of rhinitis.
RaVoR™ (Radiofrequency Volume Reduction) of the soft palate has become the standard surgical procedure to treat habitual snoring and mild sleep apnea. Multiple clinical studies confirmed the efficacy and the clinical benefit of the treatment (see abstracts). This minimally invasive treatment method preserves the structures and function of the soft palate. RaVoR™ is performed under local anesthesia; it can easily be combined with other treatments, e.g. RF-UPPP or CPAP treatment.
RaVoR™ of the tongue base is intended for patients suffering from light to moderate obstructive sleep apnea and retrolingual obstruction. RaVoR™ (Radiofrequency Volume Reduction) of the tongue base is a minimally invasive surgical treatment option for obstructions on that level. Tongue base reduction is usually combined with either conservative treatment (CPAP) or other surgical interventions (multi-level). RaVoR™ of the tongue base is performed under general anesthesia. Patients remain under supervision for at least one night.
Sutter RaVoR™ probes make oval-shaped, long lesions possible. Both shape and size allow treating a bigger area, while protecting bony structures as well as mucosa. Lesion always perfectly fit patient’s anatomy.
Sutter RaVoR™ probes make oval-shaped, long lesions possible. Both shape and size allow treating a bigger area, while protecting bony structures as well as mucosa. Lesion always perfectly fit patient’s anatomy.
The RaVoR™ bipolar electrodes as sterile packaged instruments reduce the risk of cross-contamination and eliminate the time required for a sterilization process. They also reduce the risk of downtime in the OR due to older, damaged instruments. Disposable instruments are cost-effective and save time by eliminating the need for reprocessing and maintenance.
“The RaVoR™ bipolar electrodes single - use for the reduction of the inferior turbinates are a convenient solution for my private practice. My staff and I enjoy the ease of use due to the new plug and operate feature.”
S. Grupp, MD, Freiburg (Germany)
“The radiofrequency assisted soft palate procedure is a minimally invasive, safe and quick procedure. It is well tolerated by patients. We have not observed any bleeding that needed special attention.”
D. Brehmer, MD, Göttingen (Germany)
“In my clinical practice I successfully make use of the tongue base radio- frequency procedure. My experience shows that when using this minimally invasive method together with other surgical techniques, the outcome of sleep-related breathing disorder surgery can be improved. The treatment is useful and should be considered in the treatment of patients with tongue base collapse.“
M. A. Sarte, MD, Manila (Philippines)
“RaVoR™ is a modern surgical technique showing good and long-lasting treatment results when used to reduce the volume of hypertrophic turbinates. At the same time it preserves the mucosa and its function.”
R. Romeo, MD, Rome (Italy)
Your cookie settings do not allow external content from YouTube.
RaVoR™ Bipolar Electrodes, single-use | Radiofrequency Turbinate Reduction
Discover all models in our product catalog – now conveniently available for download as a PDF file.
By delivering focused RF energy, RaVoR™ allows controlled coagulation of target tissue while limiting thermal effects on adjacent structures – an advantage in functionally sensitive areas.
RaVoR stands for Radiofrequency Volume Reduction – a technique that applies controlled thermal energy to the tissue, enabling precise coagulation with minimal thermal spread to surrounding structures.
The electrodes are intended for ENT procedures and are suitable for applications on the inferior turbinate, soft palate, tongue base, and other soft tissue structures in the head and neck region.
No, these are sterile single-use products and must be disposed of appropriately after use.
Sutter also offers reusable RaVoR™ bipolar electrodes.
Product availability is subject to regulatory approval in individual markets. Products may therefore not be available in all markets.
Cookie approval
This website uses necessary cookies to ensure the operation of the website. Third parties do not analyze user behavior. Detailed information about the use of cookies can be found in our privacy policy.
Privacy settings
Here is an overview of all cookies use
Required Cookies
These cookies are needed to let the basic page functionallity work correctly.
Show Cookie Informationen
Hide Cookie Information
Google Tag Manager
Google Tag Manager is a tag management system (TMS) that allows us to update measurement codes and associated code fragments on our website.
Provider: | |
Cookiename: | _dc_gtm_* |
Runtime: | 1 minute |
Privacy source url: | https://policies.google.com/privacy?hl=en |
Host: | www.googletagmanager.com |
Famigo Standort-Infografik
Integration of a frame on our job advertisement pages with information about the location.
Provider: | FAMIGO GmbH |
Privacy source url: | https://famigo.info/index.php/datenschutzerklaerung/ |
Cookies for Statistics
Statistic cookies anonymize your data and use it. These information will help us to learn, how the users are using our website.
Show Cookie Informationen
Hide Cookie Information
Google Analytics 4
Google Analytics is a web analytics service provided by Google that tracks and analyzes our website traffic. It provides insights into user behavior on our website and helps us to better understand our target audience and optimize our online activities.
Cookiename: | _ga, _ga_* |
Runtime: | 2 year |
Privacy source url: | https://policies.google.com/privacy?hl=en |
Host: | www.googletagmanager.com, www.google-analytics.com |
Cookies for Marketing
Marketing cookies from thrid parties will be used to show personal advertisment. They use them to track users outside of their own web page.
Show Cookie Informationen
Hide Cookie Information
Meta Pixel
Meta Pixel is a web analytics service offered by Meta that tracks and analyzes our website traffic. It provides insight into how users interact with our website and helps us understand our audience and optimize our online presence and ad targeting.
Provider: | Meta |
Cookiename: | _fbp, _fbc |
Runtime: | session, 90 day |
Privacy source url: | https://www.facebook.com/privacy/policy/ |
Host: | connect.facebook.net |
Cookies for external Content
Content for Videoplatforms und Social Media Platforms will be disabled automaticly. To see content from external sources, you need to enable it in the cookie settings.
Show Cookie Informationen
Hide Cookie Information
Youtube
YouTube uses various cookies to manage user settings and track user interactions. It is also used to unlock YouTube content.
Provider: | Google Ireland Limited, Gordon House, Barrow Street, Dublin 4, Ireland |
Cookiename: | YSC; VISITOR_INFO1_LIVE; PREF |
Runtime: | End of session; 6 months; 8 months |
Privacy source url: | https://policies.google.com/privacy?hl=en |
Host: | .youtube.com |
Vimeo
Vimeo uses various cookies to manage user settings and track user interactions. They are used to unlock Vimeo video content.
Provider: | Vimeo.com, Inc., 555 West 18th Street, New York, New York 10011, USA |
Cookiename: | player; vuid |
Runtime: | 1 year (player); 2 years (vuid) |
Privacy source url: | https://vimeo.com/privacy |
Host: | .vimeo.com |